Compare Products

Hide

Clear All

VS

Hình ảnh

RG-S7808C 10 RU Modular Campus Core Switch

Can be deployed in data centers, metropolis area networks, campus networks, or integrated scenarios of data centers and campus networks.

Model
Dòng
Tính năng nổi bật
  • Compact chassis design with a height of 10 RU, improving cabinet space utilization
  • Security defense policies, ensuring network robustness
  • VSU, delivering flexible networking capabilities and high performance
  • Hardware-level multi-protection, delivering carrier-grade reliability
  • SOE management software INC, enabling simplified and efficient O&M
Sales Enquiry
Thông số chi tiết chính View More
Features

Modular Core Switch RG-7808C

Compact chassis design with a height of 10 RU improves cabinet space utilization. A single card supports up to 52 non-combo ports, meeting the networking requirements of small and medium-sized core networks or medium-sized network aggregation scenarios.

Security Defense Policies, Ensuring Network Robustness

CPP

NFPP

CPU Protection Policy (CPP) controls the types and traffic of packets sent to the CPU, preventing CPU usage exceptions.

VSU, Delivering Flexible Networking Capabilities and High Performance

VSU technology virtualizes multiple physical switches into one logical unit with a single IP address to realize unified management, simplifying O&M.
Fast link failover within 50 to 200 milliseconds ensures nonstop transmission of critical services.

Hardware-Level Multi-Protection, Delivering Carrier-Grade Reliability

Dual-Boot Redundancy
Dual-Boot Redundancy

Two flash chips for storing boot software achieve hardware-level boot redundancy, avoiding switch boot failures due to a flash chip fault.

1+1 Supervisor Engine Redundancy

1+1 hot standby ensures nonstop switch services.

1+1 Supervisor Engine Redundancy
N+M Power Supply Redundancy

Four hot-swappable power supplies realize failover within seconds and service continuity during power replacement, ensuring link reliability.

1+1 Fan Module Redundancy

Two axial flow fans for factory delivery support 256-level speed regulation and precise temperature control, reducing energy consumption and noise.

1+1 Fan Module Redundancy

SOE Management Software INC Offers Easy and Efficient O&M

Automatic device registration and configuration after device connection, plug and play without commissioning, fast provisioning
Flexible replacement with no need form a bridge reconfiguration Auto-sensing on ports, facilitating automatic O&M
Intelligent identification and classification of terminals together with one-click access control and approvals Three-minute quick and auto onboarding
Zero-touch provisioning and plug and play Zero-touch provisioning and plug and play
Access control as well as quick onboarding Access control as well as quick onboarding
Zero-touch replacement and auto-sensing on ports Zero-touch replacement and auto-sensing on ports

Specifications

Hardware Specifications

Hareware Specifications

S7805C

S7808C

S7810C

Interface Specifications

Power module

2

2

4

Supervisor module slot

2

2

2

Line card slot

3

6

8

Switch fabric module slot

Built-in

2 (integrated with supervisor modules)

4 (2 are integrated with supervisor modules)

System Specifications

Packet forwarding rate

4,500 Mpps

9,000 Mpps

12,000 Mpps

System switching capacity

6 Tbps

12 Tbps

16 Tbps

MAC address

● Number of global MAC addresses

EB card: 64,000

DA card: 96,000 (default) and 288,000 (max.)

FA card: 80,000

FB card: 96,000

● Number of static MAC addresses

EB card: 4,000

DA card: 10,000

FA card: 4,000

● FB card: 40,000

ARP table

EB card: 10,000 (default and recommended)

DA card: underlay: 75,000; overlay: 0 (default and recommended)

FA card: underlay: 30,000; overlay: 0

FB card: underlay: 50,000; overlay: 0 (default and recommended)

Number of IPv4 unicast routes

EB card: 12,000 (default and recommended, shared with IPv6 routes) 

DA card: 12,000 (default and recommended, shared with IPv6 routes)

FA card: 12,000 (default and recommended, shared with IPv6 routes)

FB card: 134,000 (default and recommended, shared with IPv6 routes)

Number of IPv4 multicast routes

EB card: 8,000

DA card: 16,000

FA card: 8,000

FB card: 16,000

Number of IPv6 unicast routes

EB card: 6,000 (shared with IPv4 routes)

DA card: 6,000 (shared with IPv4 routes)

FA card: 6,000 (shared with IPv4 routes)

FB card: 50,000 (shared with IPv4 routes)

Number of IPv6 multicast routes

EB card: 4,000

DA card: 8,000

FA card: 4,000

FB card: 8,000

Number of ACEs

● Ingress

EB card: 3,500

DA card: 8,000

FA card: 5,000

FB card: 4,500

● Egress

EB card: 1,000

DA card: 1,000

FA card: 1,000

● FB card: 2,000

Number of VSU members

2

2

2

Dimensions and Weight

Dimensions (W x D x H)

442 mm x 451 mm x 175 mm (17.40 in. x 17.76 in. x 6.89 in., 4 RU)

442 mm x 465mm x 441.7 mm (17.40 in. x 18.31 in. x 17.39 in., 10 RU)

442.5 mm x 560 mm x 442 mm (17.42 in. x 22.05 in. x 17.40 in., 10 RU)

Weight (empty chassis and fan modules)

32.35 kg (71.32 lbs)

35.6 kg (78.48 lbs)

43.6 kg (96.12 lbs)

CPU and Storage

CPU

● Supervisor module

M7805C-CM II: 1.5 GHz quad-core processor

● Service module

EA/EB card: 1.0 GHz quad-core processor

DA/F card: 1.5 GHz quad-core processor

● Supervisor module

M7808C-CM II: 1.5 GHz quad-core processor

● Service module

EA/EB card: 1.0 GHz quad-core processor

DA/F card: 1.5 GHz quad-core processor

● Supervisor module

M7808C-CM II: 1.5 GHz quad-core processor

● Service module

EB card: 1.0 GHz quad-core processor

DA/F card: 1.5 GHz quad-core processor

● Switch fabric module

M7810C-FE-D I/M7810C-FE-F I: 1.5 GHz quad-core processor

Storage

Flash memory

M7805C-CM II: 1 GB

EA card: 512 MB

EB card: 512 MB

DA/F card: 8 GB

SDRAM

M7805C-CM II: DDRIII 4 GB

EA card: DDR3 1 GB

EB card: DDRIII 1 GB

DA card: DDR4 1 GB

F card: DDR4 2 GB

Flash memory

Supervisor module:

M7808C-CM II: 8 GB

Service module:

EA card: 512 MB

EB card: 512 MB

DA/F card: 8 GB

SDRAM

Supervisor module:

M7808C-CM II: DDR4 4 GB

Service module:

EB card: DDR3 1 GB

DA card: DDR4 1 GB

F card: DDR4 2 GB

Flash memory

Supervisor module:

M7810C-CM/M7810C-CM-F: 8 GB

Service module:

EB card: 512 MB

DA/F card: 8 GB

Switch fabric module:

M7810C-FE-D I: 8 GB

M7810C-FE-F I: 8 GB

SDRAM

Supervisor module:

M7810C-CM/M7810C-CM-F: DDR4 4 GB

Service module:

EB card: DDR3 1 GB

DA card: DDR4 1 GB

F card: DDR4 2 GB

Switch fabric module:

M7810C-FE-D I card: DDR4 1 GB

M7810C-FE-F I: DDR4 2 GB

Power and Consumption

Maximum power consumption

Chassis

RG-S7805C: < 80 W

Supervisor module:

M7805C-CM II: < 21 W

Service module:

M7800C-24SFP/12GT4XS-EB: < 85 W

M7800C-48GT4XS-EB: < 70 W

M7800C-48SFP4XS-EB: < 101 W

M7800C-24GT24SFP4XS-EB: < 88 W

M7800C-32XS4QXS-DA: < 210 W

M7800C-48GT-FA: < 75 W

M7800C-48SFP-FA: < 95 W

M7800C-48XS-FB: < 160 W

M7800C-8CQ-FB: < 130 W

Chassis

RG-S7808C: < 176 W

Supervisor module:

M7808C-CM II: < 50 W

Service module:

M7800C-24SFP/12GT4XS-EB: < 85 W

M7800C-48GT4XS-EB: < 70 W

M7800C-48SFP4XS-EB: < 101 W

M7800C-24GT24SFP4XS-EB: < 88 W

M7800C-32XS4QXS-DA: < 210 W

M7800C-48GT-FA: < 75 W

M7800C-48SFP-FA: < 95 W

M7800C-48XS-FB: < 160 W

M7800C-8CQ-FB: < 130 W

Chassis

RG-S7810C: < 432 W

Supervisor module:

M7810C-CM: < 50 W

M7810C-CM-F: < 110 W

Service module:

M7800C-24SFP/12GT4XS-EB: < 85 W

M7800C-48GT4XS-EB: < 70 W

M7800C-48SFP4XS-EB: < 101 W

M7800C-24GT24SFP4XS-EB: < 88 W

M7800C-32XS4QXS-DA: < 210 W

M7800C-48GT-FA: < 75 W

M7800C-48SFP-FA: < 95 W

M7800C-48XS-FB: < 160 W

M7800C-8CQ-FB: < 130 W

Switch fabric module:

M7810C-FE-D I: < 50 W

M7810C-FE-F I: < 105 W

Maximum output power

● RG-PA300I-F: 90 V to 180 V; Power: 300 W

180 V to 264 V; Power: 300 W

 

● RG-PA460I-F: 90 V to 180 V; Power: 460 W

180 V to 264 V; Power: 460 W

● RG-PA600I-F: 600 W

● RG-PA1600I-F:

90 V to 180 V: 12,00 W

180 V to 264 V: 1,600 W

 

● RG-PA600I: 600 W

● RG-PA1600I:

90 V to 180 V: 1,200 W

180 V to 264 V: 1,600 W

Environment and Reliability

MTBF

> 200,000 hours

Primary Airflow

● Supervisor module

Right-to-left airflow

● Service module

Right-to-rear airflow

● System power module

Built-in fan modules drawing air outward Front-to-rear airflow

● Supervisor module /Service module

Right-to-rear airflow

● System power module

Front-to-rear airflow

● Line card

Side-to-rear airflow

● Supervisor module/FE

Front-to-rear airflow

Operating temperature

0°C to 50°C (32°F to 122°F)

Storage temperature

–40°C to +70°C (–40°F to +158°F)

Operating humidity

10% to 90% RH (non-condensing)

Storage humidity

5% to 95% RH (non-condensing)

Operating altitude

–500 m to +5,000 m (–1640.42 ft. to +16404.20 ft.)

Operating noise

55.9 dB at the temperature of 35°C (95°F)

73.4 dB at the temperature of 50°C (122°F)

Interface surge protection

All electrical ports support 4 kV surge protection in common mode or 1 kV surge protection in differential mode.

Power port: 6 kV

Telecom port: 4 kV (MGMT port)

 

Software Specifications

RG-S7800C Series

Feature

Description

Ethernet switching

Jumbo frame (maximum length: 9,216 bytes)

802.3az EEE

Maximum number of VLANs that can be created: 4,094

Voice VLAN

Super-VLAN and private VLAN

MAC address-based, port-based, protocol-based, and IP subnet-based VLAN assignment

GVRP

Basic QinQ and selective QinQ

STP (IEEE 802.1.d), RSTP (IEEE 802.1w), and MSTP (IEEE 802.1s)

ERPS (G.8032)

LLDP/LLDP-MED

IP service

Static and dynamic ARP

DHCP client

DHCP relay

DHCP server

DHCP snooping

DNS

DHCPv6 client, DHCPv6 relay, and DHCPv6 snooping

Neighbor Discovery (ND) and ND snooping

Manual tunnel, automatic tunnel, and ISATAP tunnel for IPv6

GRE tunnel

IP routing

Static routing

RIP and RIPng

OSPFv2 and OSPFv3

GR

IPv4/IPv6 IS-IS

BGP4 and BGP4+

EVPN

IPv4/IPv6 VRF

Policy-based routing (PBR)

IPv4 and IPv6 ECMP

Multicast

IGMP v1/v2/v3

IGMP snooping v1/v2/v3

IGMP proxy

IGMP fast leave

PIM-DM, PIM-SM, and PIM-SSM

PIM-SSM for IPv4 and IPv6

MSDP to achieve inter-domain multicast

MLDv1 and MLDv2

Multicast static routing

MLD v1/v2 snooping

PIM-SMv6

Multicast source IP address check

Multicast source port check

MPLS

MPLS IPv6

MPLS L3VPN

MPLS 6VPE

MPLS MIB (RFC 1273, RFC 4265, and RFC 4382)

ACL and QoS

Standard IP ACLs (hardware ACLs based on IP addresses)

Extended IP ACLs (hardware ACLs based on IP addresses or TCP/UDP port numbers)

Extended MAC ACLs (hardware ACLs based on source MAC addresses, destination MAC addresses, and optional Ethernet type)

Expert-level ACLs (hardware ACLs based on flexible combinations of the VLAN ID, Ethernet type, MAC address, IP address, TCP/UDP port number, protocol type, and time range)

ACL80 and IPv6 ACL

Applying ACLs globally (hardware ACLs based on flexible combinations of the VLAN ID, Ethernet type, MAC address, IP address, TCP/UDP port number, protocol type, and time range)

ACL redirection

Port traffic identification

Port-based rate limiting

802.1p

Traffic classification based on 802.1p priorities, DSCP priorities, and IP precedences

CAR

Congestion management: SP, WRR, DRR, WFQ, SP+WRR, SP+DRR, and SP+WFQ

Congestion avoidance: tail drop, RED, and WRED

Eight queues on each port

Security

AAA

RADIUS authorization and accounting

TACACS+

Portal authentication, RADIUS, and TACACS+ login authentication

IEEE802.1X authentication, MAC address bypass (MAB) authentication, and interface-based and MAC address-based 802.1X authentication

Web authentication

Hypertext Transfer Protocol Secure (HTTPS)

SSHv1 and SSHv2

Global IP-MAC binding

ICMP

Port security

IP source guard

DAI

SAVI

ARP spoofing prevention

CPU Protect Policy (CPP) and NFPP

Various attack defense functions, including NFPP and ARP anti-attack

uRPF

Login authentication and password security

Unknown multicast packets are not sent to the CPU, and unknown unicast packets can be suppressed.

Reliability

Rapid Ethernet Uplink Protection (REUP)

Rapid Link Detection Protocol (RLDP), Layer 2 link connectivity detection, unidirectional link detection, and VLAN-based loop control

Data Link Detection Protocol (DLDP)

IPv4 VRRP v2/v3 and IPv6 VRRP

VRRP for the super-VLAN

BFD

1+1 redundancy for supervisor modules and fan modules, and N+M redundancy for power modules

Hot swapping of components

Hot patch and online installation of patches

GR for OSPF/IS-IS/BGP

BFD for VRRP/OSPF/BGP4/ISIS/ISISv6/static routing

Device virtualization

VSU

NMS and maintenance

SPAN, RSPAN, and ERSPAN

sFlow

NTP 

SNTP

FTP, TFTP, and Xmodem

SNMP v1/v2c/v3

RMON (1, 2, 3, 9)

NETCONF

CWMP

gRPC

OpenFlow Special 1.3

Flow table analysis defined by all protocols

Transmission of specified packets to the controller

Configuring the controller's IP address and port

Notifying port status changes to the controller

Web-based NMS

Console/Telnet/SSH2.0 CLI configuration

Fault alarms and auto-recovery

System operation logging

VXLAN

Layer 2 and Layer 3 VXLAN gateways

Note: The item marked with the asterisk (*) will be available in the future.

Show More
Resources All Resources
Learn about Products or Solutions
Software and Configuration
Order Information

Switches and Supervisor Modules

Model

Description

S7805C

RG-S7805C switch, which can accommodate three line cards and two supervisor modules

S7808C

RG-S7808C switch, which can accommodate six line cards and two supervisor modules

S7810C

RG-S7810C switch, which can accommodate eight service cards, two supervisor modules, and two switch fabric modules

M7805C-CM II

S7805C high-performance 2nd-generation supervisor module

M7808C-CM II

S7808C high-performance 2nd-generation supervisor module

M7810C-CM

S7810C high-performance 1st-generation supervisor module

M7810C-CM-F

S7810C high-performance 2nd-generation supervisor module



Model

Description

RG-PA300I-F

S7805C power module (AC, 300 W, 10 A)

RG-PA460I-F

S7805C power module (available for redundancy, AC, 460 W, 10 A)

RG-PA600I-F

S7808C power module (available for redundancy, AC, 600 W, 10 A)

RG-PA1600I-F

S7808C power module (available for redundancy, AC, 1600 W, 16 A)

RG-PA600I

S7810C power module (available for redundancy, AC, 600 W, 10 A)

RG-PA1600I

S7810C power module (available for redundancy, AC, 1600 W, 16 A)

Notes:

  • Different models cannot be interchanged.
  • Mandatory item, 1+1 redundancy supported, and at least one supervisor module must be configured.


Power Modules and Fan Modules

Model

Description

M7810C-FE-D I

RG-S7810C switch fabric module I

M7810C-FE-F I

RG-S7810C 2nd-generation switch fabric module



Model

Description

M7800C-48XS-FB

48 x 10GE optical ports (SFP+ and LC)

M7800C-8CQ-FB

8 x 100G Ethernet optical ports (QSFP28 and LC)

M7800C-48GT-FA

48 x GE electrical ports (RJ45)

M7800C-48SFP-FA

48 x GE optical ports (SFP+ and LC)

M7800C-32XS4QXS-DA

32 x 10GE optical ports (SFP+ and LC) + 4 x 40G Ethernet optical ports (QSFP+ and MPO)

M7800C-24GT24SFP4XS-EB

24 × GE electrical ports (RJ45) + 24 x GE optical ports (SFP and LC) + 4 x 10GE optical ports (SFP+ and LC)

M7800C-24SFP/12GT4XS-EB

24 x GE optical ports (SFP and LC) + 12 x GE electrical combo ports (RJ45) + 4 x 10GE optical ports (SFP+ and LC)

M7800C-48GT4XS-EB

48 x GE electrical ports (RJ45) + 4 x 10GE optical ports (SFP+ and LC)

M7800C-48SFP4XS-EB

48 x GE optical ports (SFP and LC) + 4 x 10GE optical ports (SFP+ and LC)


Switch Fabric Modules

Model

Description

M7800C-48XS-FB

48 x 10GE optical ports (SFP+ and LC)

M7800C-8CQ-FB

8 x 100G Ethernet optical ports (QSFP28 and LC)

M7800C-48GT-FA

48 x GE electrical ports (RJ45)

M7800C-48SFP-FA

48 x GE optical ports (SFP+ and LC)

M7800C-32XS4QXS-DA

32 x 10GE optical ports (SFP+ and LC) + 4 x 40G Ethernet optical ports (QSFP+ and MPO)

M7800C-24GT24SFP4XS-EB

24 × GE electrical ports (RJ45) + 24 x GE optical ports (SFP and LC) + 4 x 10GE optical ports (SFP+ and LC)

M7800C-24SFP/12GT4XS-EB

24 x GE optical ports (SFP and LC) + 12 x GE electrical combo ports (RJ45) + 4 x 10GE optical ports (SFP+ and LC)

M7800C-48GT4XS-EB

48 x GE electrical ports (RJ45) + 4 x 10GE optical ports (SFP+ and LC)

M7800C-48SFP4XS-EB

48 x GE optical ports (SFP and LC) + 4 x 10GE optical ports (SFP+ and LC)


Line Cards

Model

Description

M7800C-48XS-FB

48 x 10GE optical ports (SFP+ and LC)

M7800C-8CQ-FB

8 x 100G Ethernet optical ports (QSFP28 and LC)

M7800C-48GT-FA

48 x GE electrical ports (RJ45)

M7800C-48SFP-FA

48 x GE optical ports (SFP+ and LC)

M7800C-32XS4QXS-DA

32 x 10GE optical ports (SFP+ and LC) + 4 x 40G Ethernet optical ports (QSFP+ and MPO)

M7800C-24GT24SFP4XS-EB

24 × GE electrical ports (RJ45) + 24 x GE optical ports (SFP and LC) + 4 x 10GE optical ports (SFP+ and LC)

M7800C-24SFP/12GT4XS-EB

24 x GE optical ports (SFP and LC) + 12 x GE electrical combo ports (RJ45) + 4 x 10GE optical ports (SFP+ and LC)

M7800C-48GT4XS-EB

48 x GE electrical ports (RJ45) + 4 x 10GE optical ports (SFP+ and LC)

M7800C-48SFP4XS-EB

48 x GE optical ports (SFP and LC) + 4 x 10GE optical ports (SFP+ and LC)



Model

Description

M7800C-48XS-FB

48 x 10GE optical ports (SFP+ and LC)

M7800C-8CQ-FB

8 x 100G Ethernet optical ports (QSFP28 and LC)

M7800C-48GT-FA

48 x GE electrical ports (RJ45)

M7800C-48SFP-FA

48 x GE optical ports (SFP+ and LC)

M7800C-32XS4QXS-DA

32 x 10GE optical ports (SFP+ and LC) + 4 x 40G Ethernet optical ports (QSFP+ and MPO)

M7800C-24GT24SFP4XS-EB

24 × GE electrical ports (RJ45) + 24 x GE optical ports (SFP and LC) + 4 x 10GE optical ports (SFP+ and LC)

M7800C-24SFP/12GT4XS-EB

24 x GE optical ports (SFP and LC) + 12 x GE electrical combo ports (RJ45) + 4 x 10GE optical ports (SFP+ and LC)

M7800C-48GT4XS-EB

48 x GE electrical ports (RJ45) + 4 x 10GE optical ports (SFP+ and LC)

M7800C-48SFP4XS-EB

48 x GE optical ports (SFP and LC) + 4 x 10GE optical ports (SFP+ and LC)

Notes:

  • EB series line card only interchanged with D series line cards.
  • D series line card only interchanged with EB series line cards.
  • F series line card cannot be interchanged with other line cards.
Show More
Tips: Product information and performance will be affected by upgrade iteration, specific environment and other factors, so FAQ content is for reference only. For further information, please contact online support.
How would you rate your experience on this page?
Very disatisfying
Very satisfying
If you would like to offer more comment, please type in the textbox below, that would be helpful for the improvement of this page.
Submit
Thank you for your feedback!

Ruijie Networks websites use cookies to deliver and improve the website experience.

See our cookie policy for further details on how we use cookies and how to change your cookie settings.

Cookie Manager

When you visit any website, the website will store or retrieve the information on your browser. This process is mostly in the form of cookies. Such information may involve your personal information, preferences or equipment, and is mainly used to enable the website to provide services in accordance with your expectations. Such information usually does not directly identify your personal information, but it can provide you with a more personalized network experience. We fully respect your privacy, so you can choose not to allow certain types of cookies. You only need to click on the names of different cookie categories to learn more and change the default settings. However, blocking certain types of cookies may affect your website experience and the services we can provide you.

  • Performance cookies

    Through this type of cookie, we can count website visits and traffic sources in order to evaluate and improve the performance of our website. This type of cookie can also help us understand the popularity of the page and the activity of visitors on the site. All information collected by such cookies will be aggregated to ensure the anonymity of the information. If you do not allow such cookies, we will have no way of knowing when you visited our website, and we will not be able to monitor website performance.

  • Essential cookies

    This type of cookie is necessary for the normal operation of the website and cannot be turned off in our system. Usually, they are only set for the actions you do, which are equivalent to service requests, such as setting your privacy preferences, logging in, or filling out forms. You can set your browser to block or remind you of such cookies, but certain functions of the website will not be available. Such cookies do not store any personally identifiable information.

Accept All

View Cookie Policy Details

Liên hệ

Liên hệ

How can we help you?

Liên hệ

Get an Order help

Liên hệ

Get a tech support